Metdeck Warm Roof

Warm Roof Solution For Metal Roofing

Overview
The Metdeck warm roof decking board combines the superior thermal performance of Kingspan’s Kooltherm Insulation board with a WBP exterior grade plywood to provide a continuous supporting substrate for the application of long strip metal roofing, ensuring faster fixing times.

Typical U-Values

The following table of U-Values are calculated in accordance with BS/I.S EN ISO 6946:2006 (Building Components and Building Elements. Thermal Resistance and Thermal Transmittance. Calculation Method) and is based on Metdeck used in conjunction with a profiled metal deck with no ceiling finish.

Product Thickness(mm)*U-Value(W/m2K)

980.23

1080.21

1180.19

1380.16

1480.15

*Product thickness = insulation + 18mm WBP Ply Note: Calculations are based on metal roofing on Breathable membrane on Metdeck composite insulation on bitumious vapour barrier on Profiled metal deck U-Value will vary depending on fi nal fi xing arrangement to be determined by site specific wind uplift calculation NB When calculating U-values to BS / I.S. EN ISO 6946: 2006, the type of mechanical fixing used may change the thickness of insulation. For the purposes of these calculations the standard of workmanship has been assumed good and therefore the correction factor for air gaps has been ignored. NB The figures quoted are for guidance only. A detailed U-value calculation together with condensation risk analysis should be completed for each individual project.